THIS INFORMATION IS TAKEN DIRECTLY FROM THE MANUAL FOR THIS ALARM SYSTEM.
Arming Your System
Before arming the system, close all protected doors and windows, and stop movement in areas protected by motion detectors. When all zones are closed, all of the Zone Lights on the keypad will be OFF, and the “Ready” light will be ON.
If the “Trouble” light is ON, check to see which trouble conditions are present on the system. Refer to the “Displaying System Information” section of this manual for instructions on viewing trouble conditions. Be sure to correct any trouble conditions before arming your system.
If the “Bypass” light is ON, check to see which zones are bypassed. Refer to the “Displaying System Information” section of this manual for instructions on viewing bypassed zones. Ensure that all zones indicated as being bypassed are bypassed intentionally. Bypassed zones will not cause an alarm.
To arm the system, enter a 4-digit Access Code. As each digit is entered, the keypad sounder will beep. When the Access Code has been entered, the “Armed” light will come ON and the keypad will beep 6 times. If an incorrect Access Code is entered, the keypad will sound a single long tone. To correct a mistake when entering a code, press the [#] Key and enter the Access Code again.
When the “Armed” light comes ON, leave the premises through the designated Entry-Exit door before the Exit Delay expires. At the end of the Exit Delay, the “Ready” light will be shut OFF – your system is now armed.
The factory setting for the Exit Delay is 45 seconds; your installer may change this time to suit your needs. Refer to the “Arming Options” section of this manual for information on other arming functions.
Disarming Your System
Enter the premises through the designated Entry-Exit door. The keypad will sound a constant tone to indicate that the system must be disarmed.
Go to the keypad and enter an Access Code. If an error is made entering the code, press the [#] Key and enter the code again.
When a correct Access Code is entered, the “Armed” light will be shut OFF, and the sounder will be silenced – your system is now disarmed.
An Access Code must be entered before the Entry Delay expires or an alarm will sound. The factory setting for the Entry Delay is 30 seconds; your installer may change this time to suit your needs.
If an alarm occurred while the system was armed, the “Memory” light and the Zone Lights of the zones that went into alarm will FLASH for two minutes. Press the [#] Key to cancel the flashing display and return the keypad to the “Ready” mode. Refer to “Display Alarm Memory” for instructions on displaying the zones that went into alarm.